Nominal
Battery Voltages
|
12, 24,
36, 48, or 60 VDC (Single model - selectable via field programming at
start-up)
|
Maximum
Output Current
|
60 amps
@ 104° F (40°C) with adjustable current limit
|
Maximum
Solar Array STC Nameplate
|
12 VDC
systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts /
60 VDC Systems 4500 Watts
|
NEC
Recommended Solar Array STC Nameplate
|
12 VDC
systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts /
60 VDC Systems 3750 Watts
|
PV Open
Circuit Voltage (VOC)
|
150 VDC
absolute maximum coldest conditions / 145 VDC start-up and operating maximum
|
Standby
Power Consumption
|
Less
than 1 Watt typical
|
Power
Conversion Efficiency
|
98.1% @
60 Amps in at 48 VDC System voltage - Typical
|
Charging
Regulation
|
Five
Stages: Bulk, Absorption, Float, Silent and Equalization
|
Voltage
Regulation Set points
|
10 to
80 VDC user adjustable with password protection
|
Equalization
Charging
|
Programmable
Voltage Setpoint and Duration - Automatic Termination when completed
|
Battery
Temperature Compensation
|
Automatic
with optional RTS installed / 5.0 mV per °C per 2V battery cell
|
Voltage
Step-Down Capability
|
Can
charge a lower voltage battery from a higher voltage PV array - Max 150 VDC
input
|
Programmable
Auxilary Control Output
|
12 VDC
output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
|
Status
Display
|
3.1"
(8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
|
Remote
Display and Controller
|
Optional
Mate or Mate2 with RS232 Serial Communications Port
|
Network
Cabling
|
Proprietary
network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
|
Data
Logging
|
Last
128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps,
Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for
each day along with total Accumulated Amp Hours, and kW Hours of production
|
Hydro
Turbine Applications
|
Consult
factory for approved Turbines
|
Positive
Ground Applications
|
Requires
two Pole Breakers for switching both positive and Negative Conductors on both
Solar Array and Battery Connections (HUB-4 and HUB-10 cannot be used for use
in positive ground applications)
|
Operating
Temperature Range
|
Minimum
-40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated
above 40° C)
|
Conduit
Knockouts
|
One
1" (35mm)on the back; One 1" (35mm) on the left side; Two 1"
(35mm) on the bottom
|
Warranty
|
Standard
5 year / Available 10 Year
|
Weight
- Unit
|
11.65
lbs (5.3 kg)
|
- Shipping
|
14.55
lbs (6.4 kg)
|
Dimensions
- Unit
|
13.5 x
5.75 x 4" (40 x 14 x 10 cm)
|
- Shipping
|
18 x 11
x 8" (46 x 30 x 20 cm)
|
Options
|
Remote
Temperature Sensor (RTS), HUB 4,
HUB 10, MATE, MATE 2
|