Nominal
Battery Voltages
|
12, 24,
36, 48, or 60 VDC (Single model - selectable via field programming at
start-up)
|
Maximum
Output Current
|
80 amps
@ 104° F (40°C) with adjustable current limit
|
Maximum
Solar Array STC Nameplate
|
12 VDC
systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts /
60 VDC systems 6250 Watts
|
NEC
Recommended Solar Array STC Nameplate
|
12 VDC
systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts /
60 VDC Systems 5000 Watts
|
PV Open
Circuit Voltage (VOC)
|
150 VDC
absolute maximum coldest conditions / 145 VDC start-up and operating maximum
|
Standby
Power Consumption
|
Less
than 1 Watt typical
|
Power
Conversion Efficiency
|
97.5% @
80 Amps in a 48 VDC System - Typical
|
Charging
Regulation
|
Five
Stages: Bulk, Absorption, Float, Silent and Equalization
|
Voltage
Regulation Set points
|
10 to
80 VDC user adjustable with password protection
|
Equalization
Charging
|
Programmable
Voltage Setpoint and Duration - Automatic Termination when completed
|
Battery
Temperature Compensation
|
Automatic
with optional RTS installed / 5.0 mV per °C per 2V battery cell
|
Voltage
Step-Down Capability
|
Can
charge a lower voltage battery from a higher voltage PV array - Max 150 VDC
input
|
Programmable
Axillary Control Output
|
12 VDC
output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
|
Status
Display
|
3.1"
(8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
|
Remote
Display and Controller
|
Optional
Mate or Mate2 with RS232 Serial Communications Port
|
Network
Cabling
|
Proprietary
network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
|
Data
Logging
|
Last
128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts,
Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb
for each day along with total Accumulated Amp Hours, and kW Hours of
production
|
Hydro
Turbine Applications
|
Consult
factory for approved Turbines
|
Positive
Ground Applications
|
Requires
two Pole Breakers for switching both positive and Negative Conductors on both
Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use
in positive ground applications)
|
Operating
Temperature Range
|
Minimum
-40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated
above 40° C)
|
Environmental
Rating
|
Indoor
Type 1
|
Conduit
Knockouts
|
One
1" (35mm)on the back; One 1" (35mm) on the left side; Two 1"
(35mm) on the bottom
|
Warranty
|
Standard
5 year / Available 10 Year
|
Weight
- Unit
|
12.20
lbs (5.56 kg)
|
- Shipping
|
15.75
lbs (7.10 kg)
|
Dimensions
- Unit
|
16.25"
x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
|
- Shipping
|
21"
x 10.5" x 9.75" (53 x 27 x 25 cm)
|
Options
|
Remote
Temperature Sensor (RTS), HUB 4,